Druckmessgerät PG-200

Pressure gauge PG-200

  • Excellent stability
    A semiconductor chip is used as pressure a sensing element. State of the art circuit technology guarantees excellent temperature compensation.
  • Low power consumption
    Approx. 9000 hours (one year) continuous operation by 3.6 V lithium battery is expected due to the adoption time sharing operation method.
  • Easy reading with a large LCD display
  • With pressure switches function
    Two independent pressure setting points of HI and LO
  • With analog output (0 ~ 1 V)
  • Meets DIN sizes W72 × H72 × D40 mm
  • PG-200 is for non-corrosive gases.

STANDARD SPECIFICATIONS[Pa version]

  • Unless otherwise specified, the specs are defined at an ambient temperature of 25 ± 5 °C, excitation voltage of 12 V DC and battery of 3.6 VDC.
● General specifications
Pressure referenceGaugeAbsolute
Model number
(Pa unit display)
101GP102GP103GP102VP102AP
103GMP
Rated pressure range 10kPa 100kPa 1000kPa -100kPa 100 kPa(abs)
Maximum pressure 20kPa 200kPa 1500kPa 200kPa 200 kPa(abs)
Break-dawn pressure 50kPa 500kPa 2000kPa 500kPa 500 kPa(abs)
Operating temp., range 0 ~ 50°C
Compensated temp. range 0 ~ 50°C
Operating humidity 35 ~ 85%RH(No condensation)
Storage temp. − 20 ~ 70°C(Atmospheric pressure, humidity 65 %RH maximum)
Pressure medium Non-corrosive gases
Pressure portPanel type M 5
Stand type R 1/4(PT 1/4)
Net weightPanel type Approx. 130g
Stand type Approx. 330g
PowerBattery type

Lithium battery DC 3.6 V (ER6VM) Battery life 9000 h minimum

External power

DC5〜10 V、DC10〜24 V
(Selectable by electrical terminals only in case of stand type)
Consumption current : 20 mA maximum

● Display
Pressure referenceGaugeAbsolute
Model number
(Pa unit display)
101GP102GP103GP102VP102AP
103GMP
Display cycle Approx. 3 times/s
Display accuracy ± 0.5 %F.S.
± 2 counts (at 25 ± 5 °C) maximum
Thermal errorZERO ± 0.1 % F.S./°C maximum ± 0.05 % F.S./°C
± 2 counts maximum
± 0.1 % F.S./°C
± 2 counts maximum
SPAN ± 0.05 % Reading/°C ± 2 counts
Resolution 1 count
● Switch
Pressure referenceGaugeAbsolute
Model number
(Pa unit display)
101GP102GP103GP102VP102AP
103GMP
Resolution 1 count
No. of setting points 2 points of HI and LO
(one point of HI only for the external power supply version)
Switching capacity 30 VDC、40 mA(NPN open collector)
Residual voltage 1.2 VDC(When current inflow is 40 mA)
Output conditions Measured press ≧ LO set press. → LO output ON,
Measured press. ≧ HI set press. → HI output ON.
Setting method When the SET button is pressed,
HI set pressure is displayed for about 20 seconds first,
then LO set pressure is displayed for about 20 seconds.
Therefore, high and low pressure settings can be made by VR watching the display
Pressure setting range
(Pa unit display)
0.00~10.00kPa 00.0~100.0kPa 000~1000kPa 00.0~
− 100.0kPa
00.0~
100.0kPa
.000~1.000
(MPa)
Switch state indication Indicated by an LCD display (HI or LO)
when the switch output is ON.
Response Approx. 100 ms
Switching hysteresis 4 counts maximum
Analog voltage output
※1
Voltage output: 0 ~ 1 V,
Accuracy: ± 1 %F.S. (at 25 ± 5 °C),
Load: 1 kΩ minimum
Additional function Low battery indication (LO BAT)
Accessories
(for panel type only)
Attachements : Half union (for a tube of φ 6 0.D.),
and Barb fitting (for a tube of φ 4 I.D.),
one piece each.(Panel type only)
  • ※ 1 : Available only for external power type.

STANDARD SPECIFICATIONS[Non SI unit version]

  • Unless otherwise specified, the specs are defined at an ambient temperature of 25 ± 5 °C, excitation voltage of 12 V DC and battery of 3.6 VDC.
◆ General specifications
Pressure referenceGaugeAbsolute
Model number101G102G103G102VH102AH
Rated pressure range
kPa{kgf/cm2}
9.81
{1000 mmH2O}
98.1
{1}
981
{10}
-98.1
{-735 mmHg}
98.1 kPa abs
{735 mmHg abs}
Maximum pressure
kPa{kgf/cm2}
19.6
{2000 mmH2O}
196
{2}
1471
{15}
196
{1471 mmHg}
196 kPa abs
{1471 mmHg abs}
Break-dawn pressure
kPa{kgf/cm2}
49.0
{5000 mmH2O}
490
{5}
1961
{20}
490
{3678 mmHg}
490 kPa abs
{3678 mmHg abs}
Operating temp., range 0~50°C
Compensated temp. range 0~50°C
Operating humidity 35~85%RH(No condensation)
Storage temp. -20~70°C
(Atmospheric pressure, humidity 65 %RH maximum)
Pressure medium Non-corrosive gases
Pressure portPanel type M 5
Stand type R 1/4(PT 1/4)
Net weightPanel type Approx. 130g
Stand type Approx. 330g
PowerBattery type Lithium battery DC 3.6 V (ER6VM)
Battery life 9000 h minimum
External power DC5~10 V、DC10~24 V
(Selectable by electrical treminals only in case of stand type)
Consumption current : 20 mA maximum
◆ Display
Pressure referenceGaugeAbsolute
Model number101G102G103G102VH102AH
No. of digits 3 1/2
Display element LCD
Rated display range 000~1000 mmH2O .000~1.000 kgf/cm2 0.00~10.00 kgf/cm2 000~-735 ※ 2 mmHg 000~735 ※ 2 mmHg
Display cycle Approx. 3 times/s
Display accuracy ± 0.5 %F.S. ± 2 counts (at 25 ± 5 °C) maximum
Thermal errorZERO ± 0.1 % F.S./°Cmaximum ± 0.05 % F.S./°C ± 2 counts maximum ± 0.1 % F.S./°C ± 2 counts maximum
SPAN ± 0.05 % Reading/°C ± 2 counts
Resolution 1 count
◆ Switch
Pressure referenceGaugeAbsolute
Model number101G102G103G102VH102AH
No. of setting points 2 points of HI and LO
(one point of HI only for the external power supply version)
Switching capacity 30 V DC、40 mA(NPN open collector)
Residual voltage 1.2 V DC(When current inflow is 40 mA)
Output conditions Measured press ≧ LO set press. → LO output ON,
Measured press. ≧ HI set press. → HI output ON.
Setting method When the SET button is pressed,
HI set pressure is displayed for about 20 seconds first,
then LOset pressure is displayed for about 20 seconds.
Therefore, high and low pressure settings can be
made by VR watching the display.
Pressure setting range 000~1000kPa .000~1.000kPa 0.00~10.00kPa 000~ -735 ※ 3 000~735 ※ 3
Switch state indication Indicated by an LCD display (HI or LO)
when the switch output is ON.
Response Approx. 100 ms
Switching hysteresis 4 counts maximum
Analog voltage output ※ 1 Voltage output: 0 ~ 1 V, Accuracy: ± 1 %F.S.
(at 25 ± 5 °C), Load: 1 kΩ minimum
Additional function Low battery indication (LO BAT)
Accessories
(for panel type only)
Attachements : Half union (for a tube of φ 6 0.D.),
and Barb fitting
(for a tube of φ 4 I.D.),
one piece each. (Panel type
  • ※ 1:Available only for external power type.
  • ※ 2 : Measurement can be made up to “- 760 mmHg” for 102VH and up to “760 mmHg” for 102AH (Accuracy not guaranteed beyond the rated pressure.).
  • ※ 3 : Pressure setting can be made up to “– 760 mmHg” for 102VH and up to “760 mmHg” for 102AH (Accuracy not guaranteed beyond the rated pressure.).

MODEL NUMBER DESIGNATION

PG-200-102G P-3 -P

Series name

Rated pressure range

101:0~9.81 kPa

       {0~0.1 kgf/cm2}

        0~10 kPa

        (Pa unit display)
102:0~98.1 kPa

        {0~1 kgf/cm2}

        0~100 kPa

        (Pa unit display)
103:0~981 kPa

     {0~10 kgf/cm2}

        0~1 MPa

        (Pa unit display)

Pressure reference

G:Gauge
VH:Gauge(Vacuum)
AH:Absolute 
GP:Gauge
      Pa unit display

GMP:Gauge(103 type only)
         Pa unit display 
VP:Gauge(Vacuum)
      Pa unit display 
AP:Absolute
      Pa unit display

Power

Blank:Battery
3:External power
   (Analog output is available)

Installation

P:Panel type
S:Stand type

LIST OF MODEL NUMBERS

●Pa version
Model numberPressure referenceRated pressure
(Pa unit display)
Unit of displayPressure mediumInstallationPowerCAD
PG-200-101GP-1P Gauge 0~10 kPa For non-corrosive gases Panel type Battery
PG-200-101GP-3-P Gauge 0~10 kPa For non-corrosive gases Panel type External power
PG-200-101GP-S Gauge 0~10 kPa For non-corrosive gases Stand type Battery
PG-200-101GP-3-S Gauge 0~10 kPa For non-corrosive gases Stand type External power
PG-200-102GP-P Gauge 0~100 kPa For non-corrosive gases Panel type Battery
PG-200-102GP-3-P Gauge 0~100 kPa For non-corrosive gases Panel type External power
PG-200-102GP-S Gauge 0~100 kPa For non-corrosive gases Stand type Battery
PG-200-102GP-3-S Gauge 0~100 kPa For non-corrosive gases Stand type External power
PG-200-103GP-P Gauge 0~1000 kPa For non-corrosive gases Panel type Battery
PG-200-103GP-3-P Gauge 0~1000 kPa For non-corrosive gases Panel type External power
PG-200-103GP-S Gauge 0~1000 kPa For non-corrosive gases Stand type Battery
PG-200-103GP-3-S Gauge 0~1000 kPa For non-corrosive gases Stand type External power
PG-200-102VP-P Gauge 0~− 100 kPa For non-corrosive gases Panel type Battery
PG-200-102VP-3-P Gauge 0~− 100 kPa For non-corrosive gases Panel type External power
PG-200-102VP-S Gauge 0~− 100 kPa For non-corrosive gases Stand type Battery
PG-200-102VP-3-S Gauge 0~− 100 kPa For non-corrosive gases Stand type External power
PG-200-102AP-P Absolute 0~100 kPa abs kPa abs For non-corrosive gases Panel type Battery
PG-200-102AP-3-P Absolute 0~100 kPa abs kPa abs For non-corrosive gases Panel type External power
PG-200-102AP-S Absolute 0~100 kPa abs kPa abs For non-corrosive gases Stand type Battery
PG-200-102AP-3-S Absolute 0~100 kPa abs kPa abs For non-corrosive gases Stand type External power
●Non SI unit version
Model numberPressure referenceRated pressure kPa {kgf/cm2}Unit of displayPressure mediumInstallationPowerCAD
PG-200-101G-P Gauge 0~9.81{0~1000 mmH2O} mmH2O For non-corrosive gases Panel type Battery
PG-200-101G-3-P Gauge 0~9.81{0~1000 mmH2O} mmH2O For non-corrosive gases Panel type External power
PG-200-101G-S Gauge 0~9.81{0~1000 mmH2O} mmH2O For non-corrosive gases Stand type Battery
PG-200-101G-3-S Gauge 0~9.81{0~1000 mmH2O} mmH2O For non-corrosive gases Stand type External power
PG-200-102G-P Gauge 0~98.1{0~1} kgf/cm2 For non-corrosive gases Panel type Battery
PG-200-102G-3-P Gauge 0~98.1{0~1} kgf/cm2 For non-corrosive gases Panel type External power
PG-200-102G-S Gauge 0~98.1{0~1} kgf/cm2 For non-corrosive gases Stand type Battery
PG-200-102G-3-S Gauge 0~98.1{0~1} kgf/cm2 For non-corrosive gases Stand type External power
PG-200-103G-P Gauge 0~981{0~10} kgf/cm2 For non-corrosive gases Panel type Battery
PG-200-103G-3-P Gauge 0~981{0~10} kgf/cm2 For non-corrosive gases Panel type External power
PG-200-103G-S Gauge

0~981{0~10}

kgf/cm2 For non-corrosive gases Stand type Battery
PG-200-103G-3-S Gauge 0~981{0~10} kgf/cm2 For non-corrosive gases Stand type External power
PG-200-102VH-P Gauge 0~− 98.1 {0~- 735 mmHg} mmHg For non-corrosive gases Panel type Battery
PG-200-102VH-3-P Gauge 0~− 98.1 {0~- 735 mmHg} mmHg For non-corrosive gases Panel type External power
PG-200-102VH-S Gauge 0~− 98.1 {0~- 735 mmHg} mmHg For non-corrosive gases Stand type Battery
PG-200-102VH-3-S Gauge 0~− 98.1 {0~- 735 mmHg} mmHg For non-corrosive gases Stand type External power
PG-200-102AH-P Absolute 0~98.1 kPa abs {0~735 mmHg abs} mmHg For non-corrosive gases Panel type Battery
PG-200-102AH-3-P Absolute 0~98.1 kPa abs {0~735 mmHg abs} mmHg For non-corrosive gases Panel type External power
PG-200-102AH-S Absolute 0~98.1 kPa abs {0~735 mmHg abs} mmHg For non-corrosive gases Stand type Battery
PG-200-102AH-3-S Absolute 0~98.1 kPa abs {0~735 mmHg abs} mmHg For non-corrosive gases Stand type External power
  • 〈Option〉---DC3.6 V lithium batteryーOrder item: Lithium battery
  • The battery is an expendable item.The first one is provided with the unit.

ENVIRONMENTAL CHARACTERISTICS

Test itemTest conditionsPermissible change
Vibration Amplitude 1.5 mm P-P, 10 ~ 55 Hz,
3 directions for 2 hours each (packed)
Pressure indication, switch setting and analog
output (zero and span) variation: ± 1 %F.S.
maximum each. (Note: No analog output for the battery type.)
   
Shock 98.1 m/s2 , 3 directions for 3 times each (packed)
Moisture resistance 40 °C, 90 ~ 95 %RH, 240 hrs
Pressure cycling 0 ~ Rated pressure, 106 cycles

INTERNAL ELECTRICAL SCHEMATICS

INSIDE OF A PANEL

OUTLINE DIMENSIONS

Unless otherwise specified, tolerance : ± 0.5 (Unit: mm)

※Extra care should be taken with the diaphragm part. Do not touch the diaphragm directly to avoid damaging the diaphragm.