NIDEC COMPONENTS logo
NIDEC COMPONENTS logo

Liste

×

×


Produkte

Verteiler

EU-Deutsch

×

Druckmessgerät PG-30

●Um einen Kauf zu tätigen, wenden Sie sich an die Verteiler
oder nutzen Sie den stehenden Online-Shops unten.
Verkaufskanal  Überprüfen Sie die Verteiler.
VERKAUFSKANALKlicken Sie hier, um den Verteiler zu überprüfen.
Gehen Sie zum Farnell Online-Shop.
Gehen Sie zum DigiKey Online-Shop.
Gehen Sie zum MOUSER Online-Shop.

Pressure gauge PG-30

  • Compact and lightweight general-purpose pressure gauges
    Innovative general-purpose gauges of compact design (30mm sq.) and drip-proof structure (IP65).
  • Clear indication by LED
    Easy-to-see LED assures clear readings on the panel and even in a dark place.
  • Various modes and units can be selected according to applications
    Eight different pressure units
    Three analog output modes
    Eight switch output modes
  • Meet EMC standards
    EN 55011 (EMI)
    EN 61326-1 (EMS)
  • Low consumption by nondisplay mode
  • Set data protection by panel lock function

General specifications

  • Unless otherwise specified, the specs are defined at an ambient temperature of 25±5 °C and excitation voltage of 12 V DC.
Item101R102R103R
Pressure reference Gauge
Pressure medium Non-corrosive gases
Rated pressure range −10 ~10 kPa −100~100 kPa −100~1000 kPa
Maximum pressure 20kPa 200kPa 1500kPa
Break-down pressure 50kPa 500kPa 2000kPa
Operating temp. range -10~50°C
Compensated temp. range 0~50°C
Operating humidity 35~85%RH
Protection grade  In accordance with IEC IP65
Pressure port 2-Rc 1/8
Material of pressure port attachment Aluminum die-casting, silicone
Net weight Approx. 80(Including 2 m cable)
Thermal error ± 3 %F.S. (0 ~ 50 °C)
Insulation resistance 100 (DC 500 V) MΩ minimum
Dielectric strength AC500 V 1 minute(Leakage current 1 mA maximum
Input voltage 10.8~30 V DC(Including ripple percentage)
Consumption current 50mA maximum
Accessories Seal screw, M 5 connecting joint screw

Display

  • Unless otherwise specified, the specs are defined at an ambient temperature of 25 ± 5 °C and excitation voltage of 12 V DC.
Item101R102R103R
Display element Full 3-digit LED
Rated display range − 9.99~9.99 kPa − 99.9~99.9 kPa − 100~999 kPa
Multiplier settings Max. 11 settings
Negative pressure display Red LED is ON.
Display accuracy ± 1 %

Switch output

Output status NPN/PNP 2-point output (Transistor, Open collector output)
Output mode Separate mode / window comparator mode
Switching capacity 30 V DC 100 mA Short-circuit protection
Residual voltage 1.2 V maximum (NPN), 2.2 V maximum (PNP)(At load current of 100 mA)
State indication Output 1 (Green LED),Output 2 (Red LED),Lighted when output is ON.
Switch hysteresis 0~300 counts(Adjustable)
Repeatability ± 0.2 %F.S. ± 1 count (± 0.3 %F.S. maximum)
Response Approx. 5, 25, 250, 2500 ms Adjustable

Analog output

Output mode 3 modes
Output voltage
V zero : Pin=0,
V span : Pin=0 〜Pin (H)

1~5 V (G/V mode ZERO : 1 ± 0.2 V, SPAN : 4 ± 0.2 V
           R mode ZERO : 3 ± 0.2 V, SPAN : 2 ± 0.2 V)
103 R (R mode) (ZERO : 1.36 ± 0.2 V, SPAN : 3.64 ± 0.2 V)

Impedance 10 kΩ
Resolution 1/204
Response Approx. 5, 25, 250, 2500 ms Adjustable

ENVIRONMENTAL CHARACTERISTICS

Test itemTest conditions Permissible change
Vibration  10~500 Hz, 98.1 m/s2 or 1.5 mm P-P,
3 directions for 2 hours each
Amount of analog output fluctuation is permitted
by adding conversion error of 20 mV.  ※ 1
Shock 490 m/s2 , 3 directions for 3 times each
Moisture resistance 40 °C, 90~95 %RH, 240 hrs
Pressure cycling 0~Rated pressure, 106 cycles
EMC EMI : EN55011: 2007, A2 : 2007 Group 1, class B
EMS : EN61326-1 : 2006 Table 2
Pressure indication, switch operating pressure
and analog output : ± 5 %F.S. maximum during test※ 1

※1Change in the pressure indication, switch operating points and analog output.

MODEL NUMBER DESIGNATION

PG-30-101R-N

Series name

Pressure range 

101:-10~10 kPa

102:-100~100 kPa

103:-100~1000 kPa

Pressure reference

R:Compound pressure

  (Negative pressure~Positive pressure)

Switch output interface

N:NPN open collector

P:PNP open collector

LIST OF MODEL NUMBERS

Model numberRated pressure rangeSwitch output interface Pressure referenceFittingCAD
PG-30-101R-N −10~10 kPa NPN Gauge Rc 1/8
PG-30-101R-P −10~10 kPa PNP Gauge Rc 1/8
PG-30-102R-N −100~100 kPa NPN Gauge Rc 1/8
PG-30-102R-P −100~100 kPa PNP Gauge Rc 1/8
PG-30-103R-N −100~1000 kPa NPN Gauge Rc 1/8
PG-30-103R-P −100~1000 kPa PNP Gauge Rc 1/8

INTERNAL ELECTRICAL SCHEMATICS

SELECTION OF DISPLAY MULTIPLIER

  • The last digit/letter represents the selection code : Blinking red LED indicates negative pressure.
  • Diagonal column: Display multiplier cannot be selected due to resolution and number of digits.
  • (Selection code is not indicated either.)
  • Selection code is set at “1” prior to shipment.

ANALOG OUTPUT MODE

  • When shipped from our factory-101R : R mode is set at “1”, 102R : V mode is set at “3” and 103R : G mode is set at “2”.
  • The above 3 types can be set at “1”, “2” or “3”. However, the accuracy at V mode of 103R can’t be guaranteed.

SWITCH OUTPUT MODE

  • Note 1. In the Separate Mode, setting 1 corresponds to SW1, and Setting 2 corresponds to SW2.
  • Note 2. In the Window Comparator Mode, the minimum value for SW1 and SW2 corresponds to Setting 1 and the maximum value corresponds to Setting 2.

OUTLINE DIMENSIONS

ACCESSORIES (Sold separately)

NameSeries name ContentsApplicable model
Rear panel bracket set ACPG-001 Rear panel bracket and M 3 × 4 male screw (2pcs.) PG-30
Panel bracket set ACPG-002 Panel bracket and M 3 × 4 male screw (2pcs.) PG-30
Panel holder set ACPG-003 Panel holder cover
Panel holder
Panel stopper (2pcs.)
PG-30 · PG-35 · PG-75 ·
PG-35H · PG-35L
Holder cover set
(For protecting gauge operating panel)
ACPG-004 Panel holder cover
Panel holder
PG-30 · PG-35 · PG-75 ·
PG-35H · PG-35L
Holder stopper set ACPG-007 Panel holder
Panel stopper (2pcs.)
PG-30 · PG-35 · PG-75 ·
PG-35H · PG-35L

HOW TO MOUNT OPTIONAL ACCESSORIES (Sold separately)

●Die oben genannten Inhalte können ohne vorherige Ankündigung geändert werden.

Produkte

×

page top