NIDEC COMPONENTS logo
NIDEC COMPONENTS logo

LIST

×

×


Products

Distributor

US-English

×

Pressure indicator PZ-200

●To buy this product, please go to the following Online Web stores.
To the Pressure indicator “PZ-200 series” page on the DigiKey online shop
To the Pressure indicator “PZ-200 series” page on the MOUSER online shop

Pressure indicator PZ-200

  • The compact design saves the space
  • By VR, any pressure unit can be set to full scale
  • With pressure switch function (4 points setting)
  • Meets DIN sizes (72 × 72 mm)
  • Input signal: 1~5 V or 4~20 mA
⦿ COMPATIBILITY WITH SENSORS

PZ-200 shall be used with Copal's pressure transducers with Amp. and other sensors whose output signals are DC1~5 V or 4~20 mA.

⦿Caution

 Sensor that measures compound pressure can't be used with PZ-200. PZ-30 is suggested as alternative product.

STANDARD SPECIFICATIONS

  • Unless otherwise specified, the specs are defined at an ambient temperature of 25 ± 5 °C and excitation voltage of 12 VDC.

General specifications

Operating temp. range 0 ~ 50°C
Compensated temp. range 0 ~ 50°C
Operating humidity 35 ~ 85%RH (No condensation)
Storage temp. − 20 ~ 70°C(Atmospheric pressure, humidity 65 %RH maximum)
Net weight Approx. 150g
Power Power:12 ~ 24 V DC ± 10 %
Consumption current: 80 mA maximum

Imput

Input signal 1 ~ 5 V/4 ~ 20 mA(Internal switch provided)
Input impedance Approx. 120kΩ(1 ~ 5 V Input setting)
Internal resistance 51Ω(4 ~ 20 mA Input setting)
Maximum input voltage 30V
Maximum input current 70mA

Display

No. of digits 3  1/2
Display element LCD
Rated display range 0 ~ 1000
Display cycle Approx. 4 times/s
Display accuracy ± 0.1 % Reading ± 2 counts(After calibration)
Thermal errorZero point indication ± 3 counts/10 °C
Full scale indication ± 3 counts/10 °C
Resolution 1 count
Zero point variable range ± 200 counts
Full scale variable range ± 200 ~ 1000 counts
Decimal point location 102、101、100(Selected by a panel switch)
Polarity change Negative “−” indication (actuated by panel switch)
Over-range indication “ 1*** ” when the numder exceeds ± 1999 ( * : OFF)

Switch

 Pressure setting range 0 ~ 1000
Number of setting points 1(LL)、2(L)、3(H)、4(HH) 4-point output
Switching capacity 30 VDC、100 mA(NPN NPN open collector)
Residual voltage 1.2 VDC(at 100 mA of inflow currrent)
Output status 3 modes (Refer to pressure switch output function)
Setting method By setting VR
Response Approx. 100 ms
 Analog output Current output:4 〜 20 mA,
Accuracy:± 0.5 %F.S.(at 25 ± 5 °C)、
Load: 250 Ω maximum

ENVIRONMENTAL CHARACTERISTICS

Test itemTest conditionsPermissible change
Vibration Amplitude 1.5 mm P-P, 10 ~ 55 Hz,
3 directions for 2 hours each (packed)
Pressure indication, switch setting and analog
output variation: ± 1% F.S., maximum each.
Shock 98.1 m/s2 , 3 directions for 3 times each (packed)
Moisture resistance 40 °C, 90 ~ 95 %RH, 240 hrs

INSIDE OF A PANEL

OUTLINE DIMENSION

Unless otherwise specified, tolerance: ± 0.5 (Unit: mm)

※Please refer to the page of PG-200 series for panel cut dimension.

※All the “Common” connections are made inside.

CONNECTION OF PRESSURE SENSOR

※Shield should not be earthed when sensor is earthed.

SWITCH OUTPUT SCHEMATICS

●The above contents and descriptions are subject to change without notice. 