NIDEC COMPONENTS logo
NIDEC COMPONENTS logo

LIST

×

×


Products

Distributor

US-English

×

Pressure gauge PG-208

●To buy this product, please go to the following Online Web stores.
To the Pressure gauge “PG-208 series” page on the DigiKey online shop
To the Pressure gauge “PG-208 series” page on the Mouser online shop
To the Pressure gauge “PG-208 series”page on the RS components online shop

Pressure gauge PG-208

  • Excellent stability
    A semiconductor chip is used as pressure a sensing element. State of the art circuit technology guarantees excellent temperature compensation.
  • Low power consumption
    Approx. 9000 hours (one year) continuous operation by 3.6 V lithium battery is expected due to the adoption time sharing operation method.
  • Easy reading with a large LCD display
  • With pressure switches function
    Two independent pressure setting points of HI and LO
  • With analog output (0 ~ 1 V)
  • Meets DIN sizes W72 × H72 × D40 mm
  • PG-208 is corrosion resistant due to the use of stainless steel diaphragm.

STANDARD SPECIFICATIONS[Pa version]

  • Unless otherwise specified, the specs are defined at an ambient temperature of 25 ± 5 °C, excitation voltage of 12 V DC and battery of 3.6 V DC.

General
specifications

Pressure referenceGauge
Model number
(Pa unit display)
102GP103GP102VP
103GMP
Rated pressure range 100kPa 1000kPa -100kPa
Maximum pressure 200kPa 2000kPa 200kPa
Break-dawn pressure 300kPa 3000kPa 300kPa
Operating temp., range 0 ~ 50°C
Compensated temp. range 0 ~ 50°C
Operating humidity 35~85%RH(No condensation)
Storage temp. -20~70°C(Atmospheric pressure, humidity 65 %RH maximum)
Pressure medium Corrosive gases/liquids compatible with SUS316 and SUS316L ※ 1
Gravitational effect
(From vertical position to horizontal position)
Approx. 0.5% F.S. Approx. 0.05% F.S. Approx. 0.5% F.S.
Pressure port G 3/8(PF 3/8)
Net weight Approx. 390g
PowerBattery type Lithium battery 3.6 VDC (ER6VM)
Battery life 9000 h minimum
External power 5〜 10 VDC、10 〜 24 VDC
(Selectable by electrical terminals only in case of stand type)
Consumption current : 20 mA maximum

Display

No. of digits 3 1/2
Display element LCD
Rated display range
(Pa unit display)
00.0~100.0kPa 000~1000kPa 00.0~− 100.0kPa
.000~1.000(MPa)
Display cycle Approx. 3 times/s
Display accuracy ± 0.5 %F.S. ± 2 counts
(at 25 ± 5 °C) maximum
Thermal errorZERO ± 0.1 % F.S./°C ± 2 counts
SPAN ± 0.05 % Reading/°C ± 2 counts
Resolution 1 count

Switch

No. of setting points 2 points of HI and LO
(one point of HI only for the external power supply version)
Switching capacity 30 VDC、40 mA(NPN open collector))
Residual voltage 1.2 VDC(When current inflow is 40 mA)
Output conditions Measured press ≧ LO set press. → LO output ON,
Measured press. ≧ HI set press. → HI output ON.
Setting method When the SET button is pressed,
HI set pressure is displayed for about 20 seconds first, then LO set pressure is displayed for about 20 seconds.
Therefore, high and low pressure settings can bemade by VR watching the display.
Pressure setting range
(Pa unit display)
00.0~100.0kPa 000~1000kPa 00.0 ~-100.0kPa
.000~1.000(MPa)
Switch state indication Indicated by an LCD display (HI or LO)
when the switch output is ON.
Response Approx. 100 ms
Switching hysteresis 4 counts maximum
   Analog voltage output
 ※ 2
Voltage output: 0 ~ 1 V,
Accuracy: ± 1 %F.S. (at 25 ± 5 °C),
Load: 1 kΩ minimum
Additional function Low battery indication (LO BAT) 
  • ※ 1 : Pressure medium will be limited to the ones compatible with Fluoro rubber when an O-ring supplied as an accessary is used and also compatible with the material of the joints.
  • ※ 2 : Available only for external power type.

STANDARD SPECIFICATIONS[Non SI unit version]

  • Unless otherwise specified, the specs are defined at an ambient temperature of 25 ± 5 °C, excitation voltage of 12 VDC and battery of 3.6 VDC.

General specifications

Pressure referenceGauge
Model number102G103G102VH
Rated pressure range
kPa {kgf/cm2 }
98.1{1} 981{10} -98.1{-735 mmHg}
Maximum pressure
kPa {kgf/cm2 }
196{2} 1961{20} 196{1471 mmHg}
Break-dawn pressure
kPa {kgf/cm2 }
294{3} 2941{30} 294{2206 mmHg}
Operating temp., range 0 ~ 50°C
Compensated temp. range 0 ~ 50°C
Operating humidity 35 ~ 85%RH(No condensation)
Storage temp. -20~70°C(Atmospheric pressure, humidity 65 %RH maximum)
Pressure medium Corrosive gases/liquids compatible with SUS316 and SUS316L ※ 1
Gravitational effect
(From vertical position to horizontal position)
Approx. 0.5% F.S. Approx. 0.05% F.S. Approx. 0.5% F.S.
Pressure port G 3/8(PF 3/8)
Net weight Approx. 390g
PowerBattery type Lithium battery DC 3.6 V (ER6VM)
Battery life 9000 h minimum
External power 5~10 VDC、10~24 VDC
(Selectable by electrical terminals only in case of stand type)
Consumption current : 20 mA maximum

Display

No. of digits 3 1/2
Display element LCD
Rated display range(Pa unit display) .000~1.000 kgf/cm2 0.00~10.00 kgf/cm2 000~-735 ※ 2 mmHg
Display cycle Approx. 3 times/s
Display accuracy ± 0.5 %F.S. ± 2 counts (at 25 ± 5 °C) maximum
Thermal errorZERO ± 0.1 % F.S./°C ± 2 counts maximum
SPAN ± 0.05 % Reading/°C ± 2 counts
Resolution 1 count

Switch

No. of setting points 2 points of HI and LO
(one point of HI only for the external power supply version)
Switching capacity 30 V DC、40 mA(NPN open collector)
Residual voltage 1.2 V DC(When current inflow is 40 mA)
Output conditions Measured press ≧ LO set press. → LO output ON,
Measured press. ≧ HI set press. → HI output ON.
Setting method When the SET button is pressed, HI set pressure is displayed for about 20 seconds first, then LO
set pressure is displayed for about 20 seconds. Therefore, high and low pressure settings can be
made by VR watching the display.
Pressure setting range
(Pa unit display)
.000 ~ 1.000kPa 0.00 ~ 10.00kPa 000 ~ − 735 ※ 2
Switch state indication Indicated by an LCD display (HI or LO)
when the switch output is ON.
Response Approx. 100 ms
Switching hysteresis 4 counts maximum
   Analog voltage output
※ 3
Voltage output: 0 ~ 1 V,
Accuracy: ± 1 %F.S. (at 25 ± 5 °C),
Load: 1 kΩ minimum
Additional function Low battery indication (LO BAT)
  • ※ 1:Pressure medium will be limited to the ones compatible with Fluoro rubber when an O-ring supplied as an accessary is used and also compatible with the material of the joints.
  • ※ 2:Measurement can be made up to “- 760 mmHg” for 102VH and up to “760 mmHg” for 102AH (Accuracy not guaranteed beyond the rated pressure.).
  • ※ 3:Available only for external power type.

MODEL NUMBER DESIGNATION

PG-208-102G P-3 -P

Series name

Rated pressure range

101:0~9.81 kPa

       {0~0.1 kgf/cm2}

        0~10 kPa

        (Pa unit display)
102:0~98.1 kPa

        {0~1 kgf/cm2}

        0~100 kPa

        (Pa unit display)
103:0~981 kPa

     {0~10 kgf/cm2}

        0~1 MPa

        (Pa unit display)

Pressure reference

G:Gauge
VH:Gauge(Vacuum)
AH:Absolute 
GP:Gauge
      Pa unit display

GMP:Gauge(103 type only)
         Pa unit display 
VP:Gauge(Vacuum)
      Pa unit display 
AP:Absolute
      Pa unit display

Power

Blank:Battery
3:External power
   (Analog output is available)

Installation

S:Stand type

LIST OF MODEL NUMBERS

◆Pa version
Model numberPressure mediumRated pressure kPa {kgf/cm2}Unit of displayInstallationPowerCAD
PG-208-102GP-S For corrosive gases or liquids 0~100 kPa Stand type Battery
PG-208-102GP-3-S For corrosive gases or liquids 0~100 kPa Stand type External power
PG-208-103GP-3-S For corrosive gases or liquids 0~1000 kPa Stand type External power
PG-208-103GP-S For corrosive gases or liquids 0~1000 kPa Stand type Battery
PG-208-102VP-S For corrosive gases or liquids 0~− 100 kPa Stand type Battery
PG-208-102VP-3-S For corrosive gases or liquids 0~− 100 kPa Stand type External power
PG-208-103GMP-S For corrosive gases or liquids 0~1000 MPa Stand type Battery
PG-208-103GMP-3-S For corrosive gases or liquids 0~1000 MPa Stand type External power
◆Non SI unit version
Model numberPressure mediumRated pressure kPa {kgf/cm2}Unit of displayInstallationPowerCAD
➡PG-208-102G-S For corrosive gases or liquids 0~98.1{0~1} kgf/cm2 Stand type Battery
➡PG-208-102G-3-S For corrosive gases or liquids 0~98.1{0~1} kgf/cm2 Stand type External power
➡PG-208-103G-S For corrosive gases or liquids 0~981{0~10} kgf/cm2 Stand type Battery
➡PG-208-103G-3-S For corrosive gases or liquids 0~981{0~10} kgf/cm2 Stand type External power
➡PG-208-102VH-3-S For corrosive gases or liquids 0~− 98.1 {0~- 735 mmHg} mmHg Stand type External power
➡PG-208-102VH-S For corrosive gases or liquids 0~− 98.1 {0~- 735 mmHg} mmHg Stand type Battery
※The products marked ➡ are manufactured upon receipt of order basis.
〈Option〉---DC3.6 V lithium battery Order item: Lithium battery
(The battery is an expendable item.The first one is provided with the unit.)
 

ENVIRONMENTAL CHARACTERISTICS

Test itemTest conditionsPermissible change
Vibration Amplitude 1.5 mm P-P, 10 ~ 55 Hz,
3 directions for 2 hours each (packed)
Pressure indication, switch setting and analog
output (zero and span) variation: ± 1 %F.S.
maximum each. (Note: No analog output for the battery type.)
   
Shock 98.1 m/s2 , 3 directions for 3 times each (packed)
Moisture resistance 40 °C, 90 ~ 95 %RH, 240 hrs
Pressure cycling 0 ~ Rated pressure, 106 cycles

INTERNAL ELECTRICAL SCHEMATICS

OUTLINE DIMENSIONS

Extra care should be taken with the diaphragm part. Do not touch the diaphragm directly to avoid damaging the diaphragm.

●The above contents and descriptions are subject to change without notice. 