NIDEC COMPONENTS logo
NIDEC COMPONENTS logo

LIST

×

×


Products

Distributor

US-English

×

Pressure transducer (ratio metric) P-7100

  •  P-7100<br>Fitting: R1/8
    P-7100
    Fitting: R1/8
  •  P-7100<br>Fitting: M5 female
    P-7100
    Fitting: M5 female
  •  P-7100<br>Fitting: R1/8
    P-7100
    Fitting: R1/8
  •  P-7100<br>Fitting: M5 female
    P-7100
    Fitting: M5 female

Contact Us

●To buy this product, please go to the following Online Web stores.
To the Pressure transducer(ratio metric) “P-7100 series” page on the DigiKey online shop
 To the Pressure transducer(ratio metric)  “P-7100 series” page on the Mouser online shop
To the Pressure transducer(ratio metric) “P-7100 series” page on the RS components online shop

Ultra-miniature pressure sensors

  • Suitable for installing inside the narrow space of the equipment thanks to its small size and light weight
    outline dimensions φ 17×18.7mm, Net weight: Approx 19 g (M5 type)
  • High reliability (SUS316L diaphragm, oil-filled) by using double diaphragm structure
  • Supply voltage and analog output is 5±0.5V and the 0.5 ~ 4.5V(ratiometric output)
  • High accuracy by using a digital compensation circuit employing the COB (chip on board) mounting
  • Variety pressure range: 0 ~ 100kPa, -100 ~ 100kPa, 0 ~ 1MPa, 0 ~ 133.3kPa abs

Standard specifications

Media Corrosive gases/liquids compatible with SUS316L and SUS304
Operating temp.range -20~70℃
Compensated temp. range 0~50℃
Operating humidity range 35~85%RH(No condensation)
Storage temp. range -20~80℃(Atmospheric pressure, humidity 65 %RH maximum)
Insulation resistance 100MΩ minimum(500VDC)
Dielectric strength 500V AC 60 s(Leakage current 1mA maximum)
Operating voltage 5±0.5VDC
Current consumption 3mA Maximum
Sealed liquid Silicone oil
Net weight R1:Approx.22g, M5:Approx.19g

Analog output

Item/Model number102G103G102R132A
Output voltage※  0.5 ~ 4.5V   
Output limit  16.5mV ~ 95% Vopr   
Zero voltage※  0.5±0.04V   2.5±0.04V  0.5±0.1V
Span voltage※  4.0±0.04V    4.0±0.1V
Output current 1mA Maximum(Load resistance 5kΩ minimum)   
Linearity / Hysteresis ±0.5 %F.S.   
Thermal error
(Reference temp.25°C)
 Zero/Span:±0.05%F.S./°C     Zero/Span:±0.06%F.S./°C  
Response time  Approx.2ms   
Gravitational
(From horizontal position to vertical position)
 ±0.3%F.S.  ±0.05%F.S.   ±0.3%F.S.   ±0.3%F.S.

※Output voltage is proportional to the operating voltage.(ratiometric output)
The resolving power of the analog output is 11 Bits (about 0.002V/0.05%F.S).

Environment Characteristics

Test itemTest conditionsPermissible change
Vibration 10 ~ 500 Hz, 1.5 mm maximum/98.1m/s2
3 directions for 2 hours each
Analog output (Vzero, Vspan)
± 1 %F.S. maximum each after test
Shock 490m/s2,3 directions for 3 times each
Pressure cycling 0 ~ Rated pressure, 10cycles
Moisture resistance 40℃ 90~95%RH 240 hrs.

Model Number Designation

P-7100 -102GR1

Series name

Rated pressure range

102G: 0~100kPa
103G: 0~ 1.0MPa
102R: -100~100kPa 
132A: 0~133.3kPa abs

Pressure reference

G:Gauge (Positive)
R:Gauge (Compound)
A:Absolute

Fitting

R1: R1/8
M5: M5 Female

List of model numbers

Model NumberFittingPressure referenceRated pressureMaximum pressureBreak-down pressureCAD
P-7100-102G-R1 R1/8 Gauge 0~100kPa 200kPa 300kPa
P-7100-102G-M5 M5 Female Gauge 0~100kPa 200kPa 300kPa
P-7100-102R-R1 R1/8 Gauge -100~100kPa 200kPa 300kPa
P-7100-102R-M5 M5 Female Gauge -100~100kPa 200kPa 300kPa
P-7100-103G-R1 R1/8 Gauge 0~1.0MPa 2.0MPa 3.0MPa
P-7100-103G-M5 M5 Female Gauge 0~1.0MPa 2.0MPa 3.0MPa
P-7100-132A-R1 R1/8 Absolute 0~133.3kPa abs 200kPa abs 300kPa abs
P-7100-132A-M5 M5 Female Absolute 0~133.3kPa abs 200kPa abs 300kPa abs

Outline Dimensions

Unless otherwise specified, tolerance : ± 0.5 (Unit: mm)

 

Internal Circuit Diagram

●The above contents and descriptions are subject to change without notice. 

Products

×

page top