NIDEC COMPONENTS logo
NIDEC COMPONENTS logo

Liste

×

×


Produkte

Verteiler

EU-Deutsch

×

Druckmessgerät PG-35H

●Um einen Kauf zu tätigen, wenden Sie sich an die Verteiler
oder nutzen Sie den stehenden Online-Shops unten.
Verkaufskanal  Überprüfen Sie die Verteiler.
VERKAUFSKANALKlicken Sie hier, um den Verteiler zu überprüfen.
Gehen Sie zum DigiKey Online-Shop.
Gehen Sie zum MOUSER Online-Shop.

Pressure gauge PG-35H

  • For high pressure
  • For corrosive gases and liquids compatible with SUS316L stainless steel diaphragm
  • Compact
  • Light weight
  • Drip-proof structure (30 mm sq • 200 g • IP65)
  • Low consumption by nondisplay mode
  • Set data protection by panel lock function

General specifications

  • Unless otherwise specified, the specs are defined at an ambient temperature of 25±5 °C and excitation voltage of 12 VDC.
Model number104R354R
Pressure reference Gauge
Pressure medium Pressure Port R2:Corrosive hydraulic oil compatible with Iron or Nickel
Pressure Port G3:Corrosive gases/liquids compatible with Iron and Nickel
Rated pressure range -0.1~10MPa − 0.1 ~ 35MPa
Maximum pressure 20MPa 50MPa
Break-down pressure 40 MPa 50MPa
Operating temp. range -10 ~ 50°C
Compensated temp. range 0 ~ 50°C
Operating humidity 35 ~ 85%RH(No condensation)
Protection grade IP65
Type of mounting R 1/4, G 3/8
Pressure port Stem mount, Back mount
Material of pressure port attachment SUS 316L
Net weight Approx. 200(Including 2 m cable)
Thermal error ± 3 %F.S. (0 ~ 50 °C)
Insulation resistance 100 MΩ minimum
Dielectric strength 500 V AC 1 minute
Input voltage 10.8 ~ 30 V DC(Including ripple percentage)
Consumption current 50mA maximum

Display

  • Unless otherwise specified, the specs are defined at an ambient temperature of 25±5 °C and excitation voltage of 12 VDC.
Model number104R354R
Display element Full 3-digit LED
Rated display range − 0.10 ~ 9.99MPa − 00.1 ~ 35.0MPa
Multiplier settings Max. 11 settings
Display cycle Approx. 4 times/s
Negative pressure display “–” LED is ON
Display accuracy ± 2 %

Switch output

  • Unless otherwise specified, the specs are defined at an ambient temperature of 25±5 °C and excitation voltage of 12 VDC.
Output status NPN/PNP 2-point output (Transistor, Open collector output)
Output mode Separate mode / window comparator mode
Switching capacity 30 V DC 100 mA 
Residual voltage 1.2 V maximum (NPN), 2.2 V maximum (PNP)
State indication Output 1 (Green LED), Output 2 (Red LED) Lighted when output is ON.
Switch hysteresis 0 ~ 300 counts(Adjustable)
Repeatability ± 0.2 %F.S. ± 1 count
Response Approx. 5, 25, 250, 2500 ms Adjustable

Analog output

  • Unless otherwise specified, the specs are defined at an ambient temperature of 25±5 °C and excitation voltage of 12 VDC.
Output mode 3 modes
Output voltage
V zero : Pin=0,
V span : Pin=0 〜Pin (H)
1 ~ 5 V
(R mode 104R-ZERO:1.04 ± 0.2 V, SPAN : 3.96 ± 0.2 V,
              354R-ZERO:1.01 ± 0.2V, SPAN : 3.99 ± 0.2 V ;
 G mode ZERO:1 ± 0.2 V, SPAN : 4 ± 0.2 V)
※ The accuracy at V mode is not guaranteed.
Impedance 10 kΩ
Resolution 1/204(Approx. 20mV/ Approx. 0.5% F.S.)

ENVIRONMENTAL CHARACTERISTICS

Test itemTest conditionsPermissible change
Vibration 10 ~ 500 Hz, 98.1 m/s2 or 1.5 mm P-P,
3 directions for 2 hours each
Pressure indication,switch operating points
and analog output variation :
± 2 %F.S. maximum each after test
Shock 490 m/s2 , 3 directions for 3 times each
Moisture resistance 40 °C, 90~95 %RH, 240 hrs
Pressure cycling 0 ~ Rated pressure, 106 cycles

MODEL NUMBER DESIGNATION

PG - 35H-104R-NR2B

Series name

Pressure range

104:-0.1~10 MPa

354:-0.1~35 MPa

Pressure reference

R:Compound pressure

   (Negative pressure~Positive pressure)

Switch output interface

N:NPN open collector

P:PNP open collector

Fitting

R2:R 1/4

G3:G 3/8

Port

Blank:Stem mount

B:Back mount

LIST OF MODEL NUMBERS

Model numberRated pressure rangePortPressure referenceFittingSwitch output interfaceCAD
PG-35H-104R-NR2 −0.1~10 MPa Stem mount Gauge R2 (R 1/4) NPN
➡PG-35H-104R-PR2 −0.1~10 MPa Stem mount Gauge R2 (R 1/4) PNP
PG-35H-104R-NG3 −0.1~10 MPa Stem mount Gauge R2 (R 1/4) NPN
➡PG-35H-104R-PG3 −0.1~10 MPa Stem mount Gauge R2 (R 1/4) PNP
PG-35H-354R-NR2 −0.1~35 MPa Stem mount Gauge G3 (G 3/8) NPN
➡PG-35H-354R-PR2 −0.1~35 MPa Stem mount Gauge G3 (G 3/8) PNP
PG-35H-354R-NG3 −0.1~35 MPa Stem mount Gauge G3 (G 3/8) NPN
➡PG-35H-354R-PG3 −0.1~35 MPa Stem mount Gauge G3 (G 3/8) PNP
PG-35H-104R-NR2B −0.1~10 MPa Back mount Gauge R2 (R 1/4) NPN
➡PG-35H-104R-PR2B −0.1~10 MPa Back mount Gauge R2 (R 1/4) PNP
PG-35H-104R-NG3B −0.1~10 MPa Back mount Gauge R2 (R 1/4) NPN
➡PG-35H-104R-PG3B −0.1~10 MPa Back mount Gauge R2 (R 1/4) PNP
PG-35H-354R-NR2B −0.1~35 MPa Back mount Gauge G3 (G 3/8) NPN
➡PG-35H-354R-PR2B −0.1~35 MPa Back mount Gauge G3 (G 3/8) PNP
PG-35H-354R-NG3B −0.1~35 MPa Back mount Gauge G3 (G 3/8) NPN
➡PG-35H-354R-PG3B −0.1~35 MPa Back mount Gauge G3 (G 3/8) PNP

Marked ➡ is manufactured upon receipt of order basis.

INTERNAL ELECTRICAL SCHEMATICS

SELECTION OF DISPLAY MULTIPLIER

  • The last digit/letter represents the selection code : Blinking red LED indicates negative pressure.

  • Diagonal column: Display multiplier cannot be selected due to resolution and number of digits.
  • (Selection code is not indicated either.) Selection code is set at “A” prior to shipment.

ANALOG OUTPUT MODE

Selection code is set at “G” prior to shipment.

SWITCH OUTPUT MODE

  • Note 1. In the Separate Mode, setting 1 corresponds to SW1, and Setting 2 corresponds to SW2.
  • Note 2. In the Window Comparator Mode, the minimum value for SW1 and SW2 corresponds to Setting 1 and the maximum value corresponds to Setting 2.

OUTLINE DIMENSIONS

 

ACCESSORIES (Sold separately)

NameSeries nameContentsApplicable model
Panel holder set ACPG-003 Panel holder cover
Panel holder
Panel stopper (2pcs.)
PG-30 · PG-35 · PG-75 ·
PG-35H · PG-35L
Holder cover set
(For protecting gauge operating panel)
ACPG-004 Panel holder cover
Panel holder
PG-30 · PG-35 · PG-75 ·
PG-35H · PG-35L
Holder stopper set ACPG-007 Panel holder
Panel stopper (2pcs.)
PG-30 · PG-35 · PG-75 ·
PG-35H · PG-35L

HOW TO MOUNT OPTIONAL ACCESSORIES (Sold separately)

◆PG-30 • PG-35 • PG-35H • PG-35L • PG-75 Panel cut holder set & holder cover set

◆Panel holder cover set

 

Piping

  • Use a wrench on the aluminum die-casting. Do not hold the plastic case when tightening.
  • Apply sealing tape at the male screw area(R2 type)to protect against air leaks.