Druckmessgerät PG-35

●Um einen Kauf zu tätigen, wenden Sie sich an die Verteiler
oder nutzen Sie den stehenden Online-Shops unten.
Verkaufskanal  Überprüfen Sie die Verteiler.
VERKAUFSKANALKlicken Sie hier, um den Verteiler zu überprüfen.
Gehen Sie zum DigiKey Online-Shop.
Gehen Sie zum MOUSER Online-Shop.

Pressure gauge PG-35

  • Both absolute pressure type and compound pressure type are available
    Compound pressure type measures negative and positive gauge pressure.
  • Compact and lightweight general-purpose pressure gauges
    Innovative general-purpose gauges of compact design (30mm sq.) and drip-proof structure (IP65).
  • Clear indication by LED
    Easy-to-see LED assures clear readings on the panel and even in a dark place.
  • Various modes and units can be selected according to applications
    Eight different pressure units
    Three analog output modes
    Eight switch output modes
  • Meet EMC standards
    EN 55011 (EMI) EN 61326-1 (EMS)
  • Low consumption by nondisplay mode
  • Set data protection by panel lock function

General specifications

  • Unless otherwise specified, the specs are defined at an ambient temperature of 25±5 °C and excitation voltage of 12 VDC.
 Model number102R103R102A
Pressure reference Gauge Absolute
Pressure medium Corrosive gases/liquids compatible with SUS 316L
Rated pressure range − 100 ~ 100 kPa − 100 ~ 1000 kPa 0 ~ 100 (abs) kPa
Maximum pressure 200kPa 2000kPa 200 (abs)kPa
Break-down pressure 300kPa 3000 kPa 300 (abs) kPa
Operating temp. range -10 ~ 50°C
Compensated temp. range 0 ~ 50°C
Operating humidity 35 ~ 85%RH
Protection grade In accordance with IEC IP65
Pressure Port R 1/4, G 3/8, G 1/4, 9/16-18UNF
Type of mounting Stem mount, Back mount
Material of pressure port attachment SUS 316L
Net weight Approx. 150g(Including 2 m cable)
Thermal error ± 3 %F.S. (0 ~ 50 °C)
Insulation resistance 100 (DC 500 V) MΩ minimum
Dielectric strength 500 VAC 1 minute(Leakage current 1 mA maximum)
Input voltage 10.8 ~ 30 VDC(Including ripple percentage)
Consumption current 50mA maximum
Accessories  “O” rings are supplied (G 3/8 : P18, G 1/4 : P15)

Display

  • Unless otherwise specified, the specs are defined at an ambient temperature of 25±5 °C and excitation voltage of 12 VDC.
 Model number102R103R102A
Display element Full 3-digit LED
Rated display range − 99.9 ~ 99.9kPa − 100 ~ 999kPa 0.0 ~ 99.9 kPa
Multiplier settings Max. 11 settings
Negative pressure display Red LED is ON.
Display accuracy ± 1 %

Switch output

  • Unless otherwise specified, the specs are defined at an ambient temperature of 25±5 °C and excitation voltage of 12 VDC.
Output status NPN/PNP 2-point output (Transistor, Open collector output)
Output mode Separate mode / window comparator mode
Switching capacity 30 VDC 100 mA Short-circuit protection
Residual voltage 1.2 V maximum (NPN), 2.2 V maximum (PNP)(At load current of 100 mA)
State indication Output 1 (Green LED), Output 2 (Red LED) Lighted when output is ON.
Switch hysteresis 0 ~ 300 counts(Adjustable)
Repeatability ± 0.2 %F.S. ± 1 count (± 0.3 %F.S. maximum)
Response Approx. 5, 25, 250, 2500 ms Adjustable

Analog output

  • Unless otherwise specified, the specs are defined at an ambient temperature of 25±5 °C and excitation voltage of 12 VDC.
Output mode 3 modes
Output voltage
V zero : Pin=0,
V span : Pin=0 〜Pin (H)
1 ~ 5 V (G/V mode  ZERO : 1 ± 0.2 V, SPAN : 4 ± 0.2 V ;
             R mode ZERO : 3 ± 0.2 V, SPAN : 2 ± 0.2 V)
103 R (R mode) (ZERO : 1.36 ± 0.2 V SPAN : 3.64 ± 0.2 V)
Impedance 10 kΩ
Resolution 1/204(Approx. 20mV/ Approx. 0.5% F.S.)
Response Approx. 5, 25, 250, 2500 ms Adjustable

MODEL NUMBER DESIGNATION

※High corrosion resistance type
PG - 35-102R-NR2B

Series name

Pressure range 

102R:-100~100 kPa

102A:0~100 kPa

103R:-100~1000 kPa

         

Pressure reference

R:Compound pressure [Negative pressure ~ Positive pressure]

A:Absolute pressure [Absolute vacuum ~ Barometic pressure]

Switch output interface

N:NPN open collector

P:PNP open collector

Fitting

R2:R 1/4(With M5 female screw)

GF:G 3/8 (Flush diaphragm type)

G2:G 1/4 (With M5 female screw)

VC:9/16-18UNF (Gusket joint)

Port

Blank:Stem mount

B:Back mount

LIST OF MODEL NUMBERS

Model numberRated pressure rangePressure referenceFittingType of mountingSwitch output interfaceCAD
PG-35-102R-NR2 −100~100 kPa Gauge R 1/4 Stem mount NPN
➡PG-35-102R-NR2B −100~100 kPa Gauge R 1/4 Back mount NPN
PG-35-102R-PR2 −100~100 kPa Gauge R 1/4 Stem mount PNP
➡PG-35-102R-PR2B −100~100 kPa Gauge R 1/4 Back mount PNP
PG-35-102R-NGF −100~100 kPa Gauge G 3/8 Stem mount NPN
PG-35-102R-PGF −100~100 kPa Gauge G 3/8 Stem mount  PNP
PG-35-102R-NVC −100~100 kPa Gauge 9/16-18UNF Stem mount NPN
➡PG-35-102R-NVCB −100~100 kPa Gauge 9/16-18UNF Back mount NPN
PG-35-102R-PVC −100~100 kPa Gauge 9/16-18UNF Stem mount PNP
➡PG-35-102R-PVCB −100~100 kPa Gauge 9/16-18UNF Back mount PNP
PG-35-102R-NG2 −100~100 kPa Gauge G 1/4 Stem mount NPN
PG-35-102R-PG2 −100~100 kPa Gauge G 1/4 Stem mount PNP
PG-35-103R-NR2 −100~1000 kPa Gauge R 1/4 Stem mount NPN
➡ PG-35-103R-NR2B −100~1000 kPa Gauge R 1/4 Back mountt NPN
PG-35-103R-PR2 −100~1000 kPa Gauge R 1/4 Stem mount PNP
➡PG-35-103R-PR2B −100~1000 kPa Gauge R 1/4 Back mount PNP
PG-35-103R-NGF −100~1000 kPa Gauge G 3/8 Stem mount NPN
PG-35-103R-PGF −100~1000 kPa Gauge G 3/8 Stem mount  PNP
PG-35-103R-NVC −100~1000 kPa Gauge 9/16-18UNF Stem mount NPN
➡PG-35-103R-NVCB −100~1000 kPa Gauge 9/16-18UNF Back mountt NPN
PG-35-103R-PVC −100~1000 kPa Gauge 9/16-18UNF Stem mount PNP
➡PG-35-103R-PVCB −100~1000 kPa Gauge 9/16-18UNF Back mount PNP
PG-35-103R-NG2 −100~1000 kPa Gauge G 1/4 Stem mount NPN
PG-35-103R-PG2 −100~1000 kPa Gauge G 1/4 Stem mount PNP
PG-35-102A-NR2 0~100 kPa abs Absolute R 1/4 Stem mount NPN
➡PG-35-102A-NR2B 0~100 kPa abs Absolute R 1/4 Back mount NPN
PG-35-102A-PR2 0~100 kPa abs Absolute R 1/4 Stem mount PNP
➡PG-35-102A-PR2B 0~100 kPa abs Absolute R 1/4 Back mount PNP
PG-35-102A-NGF 0~100 kPa abs Absolute G 3/8 Stem mount NPN
PG-35-102A-PGF 0~100 kPa abs Absolute G 3/8 Stem mount PNP
PG-35-102A-NVC 0~100 kPa abs Absolute 9/16-18UNF Stem mount NPN
➡PG-35-102A-NVCB 0~100 kPa abs Absolute 9/16-18UNF Back mount NPN
PG-35-102A-PVC 0~100 kPa abs Absolute 9/16-18UNF Stem mount PNP
➡PG-35-102A-PVCB 0~100 kPa abs Absolute 9/16-18UNF Back mount PNP
PG-35-102A-NG2 0~100 kPa abs Absolute G 1/4 Stem mount NPN
PG-35-102A-PG2 0~100 kPa abs Absolute G 1/4 Stem mount PNP

The products marked ➡ are manufactured upon receipt of order basis.

ENVIRONMENTAL CHARACTERISTICS

Test itemTest conditionsPermissible change
Vibration 10 ~ 500 Hz, 98.1 m/s2 or 1.5 mm P-P,
3 directions for 2 hours each
Amount of analog output fluctuation is permitted
by adding conversion error of 20 mV.

Shock 490 m/s2 , 3 directions for 3 times each
Moisture resistance 40 °C, 90 ~ 95 %RH, 240 hrs
Pressure cycling 0 ~ Rated pressure, 106 cycles
EMC EMI : EN55011: 2007, A2 : 2007 Group 1, class B
EMS : EN61326-1 : 2006 Table 2
Pressure indication, switch operating pressure and analog output : ± 5 %F.S. maximum during test ※ 1

※1 Change in the pressure indication, switch operating points and analog output.

INTERNAL ELECTRICAL SCHEMATICS

SELECTION OF DISPLAY MULTIPLIER

  • The last digit/letter represents the selection code : Blinking red LED indicates negative pressure.
  • Diagonal column: Display multiplier cannot be selected due to resolution and number of digits.
  • (Selection code is not indicated either.)
  • Selection code is set at “1” prior to shipment.

ANALOG OUTPUT MODE

  • When shipped from our factory : 102R : V mode is set at “3” and 102A, 103R : G mode is set at “2”.
  • In case of 102R and 103R, R/G/V mode can be set at “1”, “2” or “3”
  • (However, the accuracy at V mode of 103R can’t be guaranteed). 102A : Only G mode can be set.

 

SWITCH OUTPUT MODE

  • Note 1. In the Separate Mode, setting 1 corresponds to SW1, and Setting 2 corresponds to SW2.
  • Note 2. In the Window Comparator Mode, the minimum value for SW1 and SW2 corresponds to Setting 1 and the maximum value corresponds to Setting 2.

OUTLINE DIMENSIONS

Unless otherwise specified tolerance : ± 0.5 (Unit: mm)

ACCESSORIES (Sold separately)

NameSeries nameContentsApplicable model
Panel holder set ACPG-003 Panel holder cover
Panel holder
Panel stopper (2pcs.)
PG-30·PG-35·PG-75·
PG-35H·PG-35L
Holder cover set
(For protecting gauge operating panel)
ACPG-004 Panel holder cover
Panel holder
PG-30·PG-35·PG-75·
PG-35H·PG-35L
Holder stopper set ACPG-007 Panel holder
Panel stopper (2pcs.)
PG-30·PG-35·PG-75·
PG-35H·PG-35L

HOW TO MOUNT OPTIONAL ACCESSORIES (Sold separately)

 

Installation

◆Tube at atmospheric pressure intake

If there is any possibility that the sensor may become wet with oil or water, which may enter the case through the air intake, connect a silicon tube, or similar, to the intake and position the end of the tube in a suitably safe place. Be sure not to bend the tube or block the end of the tube.

◆Piping

Use a wrench (13mm) on the aluminum die-casting. Do not hold the plastic case when tightening. Apply sealing tape at the male screw area to protect against air leaks. If mounting with an angled bracket, the maximum torque of the M3 screws should be less than 0.3N ·m.
When using the accessories sealing or fitting screw, bind up the seal tape around the sealing screw one and a half or two turns, and screw it in the pressure port by hand without damaging the screw thread. After then, tighten the screw sufficiently with wrench.(Recommended torque:Plastic screw 3.0N·m, Metal screw 10.0N·m maximum)

Customization

We also offer customized solutions. Please contact your local sales office for details.
Model number Shape and other customization
PG-35-102R-NR2-011 Bracket (mounting plate) supplied
PG-35-102R-NR2-105 Default mode (X 1 <multiplier factor>, V mode <analog output>, separate mode <switch output>), Pressure setting (P1:30kPa / P2 :50kPa, 10ms<hysteresis>, 0 (digital filter))
PG-35-102R-NR2B-128 Panel holder set (ACPG-003) separately packed and suuplied
PG-35-102R-PR2-021 Tube for vent hole supplied. Measures against coolant intrusion(application of epoxy around a cable bush, and protection cover for panel sheet)
PG-35-103R-NS2 Fitting : 1/4 Swagelok tubing
●Die oben genannten Inhalte können ohne vorherige Ankündigung geändert werden.