NIDEC COMPONENTS logo
NIDEC COMPONENTS logo

Liste

×

×


Produkte

Verteiler

EU-Deutsch

×

Druckschalter PS60

●Um einen Kauf zu tätigen, wenden Sie sich an die Verteiler
oder nutzen Sie den stehenden Online-Shops unten.
Verkaufskanal  Überprüfen Sie die Verteiler.
VERKAUFSKANALKlicken Sie hier, um den Verteiler zu überprüfen.
Gehen Sie zum DigiKey Online-Shop.
Gehen Sie zum MOUSER Online-Shop.

PRESSURE SWITCHES WITH GAUGE

  • Applicable for negative through positive pressure with 10 mm thick slim housing
  • Suitable for use in clean rooms with easy-to-use push keys
  • Plug-in connector is provided for easy installation and maintenance
  • Space saving and mountable on DIN rails
  • Data protection by panel lock system
  • Low consumption by nondisplay mode

General specifications

  • Unless otherwise specified, the specs are defined at an ambient temperature of 25 ± 5 °C and excitation voltage of 24 V DC.
Item 102R302R103R
Pressure reference Gauge
Rated pressure range −100 ~ 100kPa −100 ~ 300kPa −100 ~ 1000kPa
Maximum pressure 200kPa 600kPa 1500kPa
Break-down pressure 500kPa 1000kPa 2000kPa
Operating temp. range −10 ~ 50°C
Compensated temp. range 0 ~ 50°C
Operating humidity 35 ~ 85%RH(No condensation)
Storage temp. −20 ~ 70°C(Atmospheric pressure, humidity 65 %RH maximum))
Pressure medium Non-corrosive gases
Insulation resistance 100 MΩ min.(500 V DC)
Thermal error ± 3 %F.S. (0 ~ 50 °C)
Dielectric strength 500 V  AC, 60 s(Leakage current 1 mA maximum)
Pressure port M5 Female screw
Net weight Approx. 50g(Includihg cable)
Supply voltage 12 ~ 24 V ± 10 %(Including ripple percentage)
Consumption current 30mA max.
Accessories PS60 cable, DIN rail adaptor

Switch output

  • Unless otherwise specified, the specs are defined at an ambient temperature of 25 ± 5 °C and excitation voltage of 24 V DC.
No. of outputs 2
Output interface Open collector output (NPN or PNP)
Setting method Adjustable by panel switch
Adjustable range −110 kPa (approx.) ~ “999” counts
Display Red LED ON
Repeatability ± 0.3 %F.S. maximum
Switch hysteresis 0 ~ 30 counts
Switching capacity 30 V 100 mA maximum
Residual voltage 1.2 V maximum(NPN), 2.2V maximum (PNP)
Response Approx. 5, 25, 250ms

Display

  • Unless otherwise specified, the specs are defined at an ambient temperature of 25 ± 5 °C and excitation voltage of 24 V DC.
Item102R302R103R
Display element 3-digit LED
Rated display range −100 ~ 100 kPa −100 ~ 300 kPa −0.10 ~ 1.00 MPa
Display accuracy 0 〜 50℃
(Reference temp. 25℃)
± 1 %F.S.
Resolution 1 count

ENVIRONMENTAL CHARACTERISTICS

Test itemTest conditionsPermissible change
Vibration 10 ~ 500 Hz, 1.5 mm maximum/98.1 m/s2 ,
3 directions for 2 hours each
Pressure indication and switch operating output :
± 2 %F.S., maximum each after test


Shock 196 m/s2 , 3 directions for 3 times each
Moisture resistance 40 °C, 90 ~ 95 %RH, 240 hrs
Pressure cycling 0 ~ Rated pressure, 106 cycles
EMC EMI : EN55011: 2007, A2 : 2007 Group 1, class B
EMS : EN61326-1 : 2006 Table 2
Pressure indication and switch operating output, alalog
output : ± 5 %F.S., maximum during test

MODEL NUMBER DESIGNATION

PS60-102R-NMCN

Series name

Rated pressure range

102:−100 ~ 100 kPa

103:−100 ~ 1000 kPa

302:−100 ~ 300 kPa

Pressure reference

R:Compound pressure (Negative pressure ~ Positive pressure)

Switch output interface

N:NPN open collector

P:PNP open collector

Pressure port

M:M5 female screw

Signal / power cable pullout method

CN:Connector pullout

LIST OF MODEL NUMBERS

Model numberRated pressurePressure portOutput interfaceCAD
PS60-102R-NMCN −100 ~ 100 kPa M5 Female screw NPN
PS60-102R-PMCN −100 ~ 100 kPa M5 Female screw PNP
PS60-302R-NMCN −100 ~ 300 kPa M5 Female screw NPN
PS60-302R-PMCN −100 ~ 300 kPa M5 Female screw PNP
PS60-103R-NMCN −100 ~ 1000 kPa M5 Female screw NPN
PS60-103R-PMCN −100 ~ 1000 kPa M5 Female screw PNP

CIRCUIT DIAGRAMS

SWITCH OUTPUT MODE

  • Note 1. In the Separate Mode, setting 1 corresponds to SW1, and Setting 2 corresponds to SW2.
  • Note 2. In the Window Comparator Mode, the minimum value for SW1 and SW2 corresponds to Setting 1 and the maximum value corresponds to Setting 2.

DISPLAY RANGE

  • Display range can be selected as the table.
  • Note) “–” on the table indicates that it is not selectable in relation to resolution and display lines.
  • ※ : In terms of setting display range, please verify the default mode.

OUTLINE DIMENTIONS

 

Accessories

●Die oben genannten Inhalte können ohne vorherige Ankündigung geändert werden.